Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
BASETRAP_1.3.6.1.4.1.2011.5.25.129.2.5.12 hwPortPhysicalEthFullDuplexClear

BASETRAP_1.3.6.1.4.1.2011.5.25.129.2.5.12 hwPortPhysicalEthFullDuplexClear

Description

BASETRAP/4/HALFDUPLEXCLEAR: OID [oid] The port works in full duplex mode. (EntityPhysicalIndex=[INTEGER], BaseTrapSeverity=[INTEGER], BaseTrapProbableCause=[INTEGER], BaseTrapEventType=[INTEGER], EntPhysicalName="[STRING]", RelativeResource="[STRING]")

The interface working mode changed to full duplex.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.129.2.5.12 Warning communicationsAlarm(2)

Parameters

Name Meaning
[oid] Indicates the OID of the alarm.
EntityPhysicalIndex Indicates the interface index.
BaseTrapSeverity Indicates the alarm severity.
BaseTrapProbableCause Indicates the alarm cause.
BaseTrapEventType Indicates the alarm type.
EntPhysicalName Indicates the interface name.
RelativeResource Indicates the relative resource.

Impact on the System

The interface alternates between Up and Down states.

Possible Causes

The interface changes from half duplex to full duplex mode.

Procedure

  1. Check whether the current duplex mode of the interface is correct according to networking requirements.

    • If so, the alarm handling ends.
    • If not, go to step 2.

  2. Run the duplex half or auto duplex half command to configure the interface to work in half duplex mode.