No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

S9300, S9300E, and S9300X V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ENTITYEXTTRAP_1.3.6.1.4.1.2011.5.25.31.2.2.6 hwEntityOutputRateThresholdAlarmResume

ENTITYEXTTRAP_1.3.6.1.4.1.2011.5.25.31.2.2.6 hwEntityOutputRateThresholdAlarmResume

Description

ENTITYEXTTRAP/4/OUTUSAGERES:OID [oid] Output flow bandwidth usage fell below the threshold. (SlotID=[STRING], UnitID=[INTEGER], PortID=[STRING], PeerSlotID=[STRING], CurUsage=[INTEGER], Threshold=[INTEGER])

The channel bandwidth usage on the channel of the board falls below the alarm recovery threshold.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.31.2.2.6 Warning qualityOfServiceAlarm(3)

Parameters

Name Meaning
OID Indicates the ID of a MIB object.
SlotID Indicates the slot ID.
UnitID Indicates the chip ID.
PortID Indicates the port name of the HG channel.
PeerSlotID Indicates the slot ID of the peer board.
CurUsage Indicates the current bandwidth usage.
NOTE:

If the current bandwidth usage cannot be obtained, it displays 0.

Threshold Indicates the bandwidth usage alarm recovery threshold.

Impact on the System

None

Possible Causes

The outbound bandwidth usage of the HG channel falls below the alarm recovery threshold.

Procedure

  1. This alarm is informational and no action is required.

Related Information

None

Translation
Download
Updated: 2019-08-21

Document ID: EDOC1000142054