Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
FIB_1.3.6.1.4.1.2011.5.25.129.2.9.4 hwFIBOverloadFwResume

FIB_1.3.6.1.4.1.2011.5.25.129.2.9.4 hwFIBOverloadFwResume

Description

FIB/1/RECOVEROVLDFRD: OID [oid] The interface board changes from the overload forwarding state to the normal state. (EntityPhysicalIndex=[INTEGER], HwBaseTrapSeverity=[INTEGER], HwBaseTrapProbableCause=[INTEGER], HwBaseTrapEventType=[INTEGER], HwFibOverloadModule=[INTEGER], entPhysicalName=[STRING])

o

The trap was generated when the interface board was recovered from the overload forwarding state.

Attribute

Alarm ID Alarm Severity Alarm Type

1.3.6.1.4.1.2011.5.25.129.2.9.4

Critical

equipmentAlarm(5)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

EntityPhysicalIndex

Indicates the index of the entity.

HwBaseTrapSeverity

Indicates the alarm severity.

HwBaseTrapProbableCause

Indicates possible causes.

HwBaseTrapEventType

Indicates the alarm type.

HwFibOverloadModule

Indicates overloaded modules:
  • 1: IPv4 module
  • 2: IPv6 module

entPhysicalName

Indicates the name of the entity.

Impact on the System

The interface board was recovered from the overload forwarding state.

Possible Causes

When the interface board was in overload forwarding status, the command to recover the interface board from the overload forwarding state was configured.

Procedure

  1. Run the display fib overload state command to check whether the current IPv4 FIB module on the interface board works normally.

    • If so, go to Step 2.
    • If not, go to Step 3.

  2. Run the display ipv6 fib overload state command to check whether the current IPv6 FIB module on the interface board works normally.

    • If so, go to Step 4.
    • If not, go to Step 3.

  3. Collect alarm information and configuration information, and then contact technical support personnel.