Alarm Handling

S9300, S9300E, and S9300X V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
BASETRAP_1.3.6.1.4.1.2011.5.25.129.2.5.13 hwPortPhysicalPortTypeChange

BASETRAP_1.3.6.1.4.1.2011.5.25.129.2.5.13 hwPortPhysicalPortTypeChange

Description

BASETRAP/4/PORTTYPECHG: OID [oid] Physical entity port type changed. (EntityPhysicalIndex=[INTEGER], BaseTrapSeverity=[INTEGER], BaseTrapProbableCause=[INTEGER], BaseTrapEventType=[INTEGER], EntPhysicalName="[OCTET]", EntityPhysicalLastPortType=[INTEGER], EntityPhysicalCurPortType=[INTEGER])

The alarm is generated when the interface type is changed through commands.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.129.2.5.13 Warning equipmentAlarm (5)

Parameters

Name Meaning
[oid] Indicates the ID of the MIB object.
EntityPhysicalIndex Indicates the entity index.
HwBaseTrapSeverity Indicates the severity level of the alarm.
HwBaseTrapProbableCause Indicates the possible cause of the alarm.
HwBaseTrapEventType Indicates the alarm type. Alarms are classified into the following types:
  • communicationsAlarm (2): alarm for communication problems
  • qualityOfServiceAlarm (3): alarm for service quality
  • processingErrorAlarm (4): alarm for wrong operations
  • equipmentAlarm (5): alarm for the equipment
  • environmentalAlarm (6): alarm for the environment

This alarm is an alarm of the equipmentAlarm type, that is, the alarm for the equipment.

EntPhysicalName Indicates the entity name.
hwBaseTrapLastPortType Indicates the interface type before the change.
hwBaseTrapCurPortType Indicates the current interface type.

Impact on the System

Services are not affected.

Possible Causes

The interface type is changed through the commands.

Procedure

  1. This log is normal operation information and does not need to be processed.

Related Information

None

Translation