No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

S9300, S9300E, and S9300X V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
RMON_1.3.6.1.2.1.16.0.2 fallingAlarm

RMON_1.3.6.1.2.1.16.0.2 fallingAlarm

Description

RMON/4/ALARMFALL:OID [OID] Alarm table [alarm-table-index] monitors [sample-object-oid] with the sample type being [sample-type], and the sampled alarm value [alarm-value] is less than or equal to [falling-value].

The value of the alarm entity was lower than fallingthreshold.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.2.1.16.0.2 Warning environmentalAlarm(6)

Parameters

Name Meaning

OID

Indicates the MIB object ID of the alarm.

alarm-table-index

Indicates the index of the alarm entry.

sample-object-oid

Indicates the OID of the sampled object.

sample-type

Indicates the type of the sampled alarm.

alarm-value

Indicates the alarm value.

falling-value

Indicates the lower threshold of the alarm.

Impact on the System

None.

Possible Causes

Cause 1:

If the current sampled value was less than or equal to this threshold, and the last sampled value was greater than this threshold, the alarm was generated.

Cause 2:

After this alarm entry became valid, when the first sampled value was less than or equal to this threshold, and the values of fallingAlarm, risingAlarm, and risingOrFallingAlarm were equal, the alarm was generated.

Procedure

  • This alarm is triggered only when the lower interface traffic monitoring threshold configured using the rmon alarm command is reached. It is a user-configured monitoring alarm and does not affect services. Therefore, no action is required.

Related Information

None.