Alarm Handling

S9300, S9300E, and S9300X V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.3.3 hwCardFail 135194

ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.3.3 hwCardFail 135194

Description

ENTITYTRAP/2/CARDFAIL: OID [oid] Card become failure for some reason. (Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityTrapEntType=[INTEGER], EntityTrapFaultID=[INTEGER])

Some functions on a card fail.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.219.2.3.3 Major equipmentAlarm(5)

Parameters

Name Meaning
OID Indicates the ID of the MIB object.
Index Indicates the alarm index.
EntityPhysicalIndex Indicates the physical entity index.
PhysicalName Indicates the name of the physical entity where the alarm is generated.
EntityTrapEntType Indicates the alarm type.
EntityTrapFaultID Indicates the error code of the alarm, which is 135194.

Impact on the System

The IIC bus cannot be accessed normally.

Possible Causes

The IIC bus has failed.

Procedure

  • Remove and install the card and then check whether the alarm is cleared.

    • If so, the alarm handling ends.
    • If not, go to step 2.

  • Replace the card and check whether the alarm is cleared.

    • If so, the alarm handling ends.
    • If not, collect alarm information and configuration information, and then contact technical support personnel.