Alarm Handling

S9300, S9300E, and S9300X V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
DLDP_1.3.6.1.4.1.2011.5.25.173.3.4 hwDldpLoopResume

DLDP_1.3.6.1.4.1.2011.5.25.173.3.4 hwDldpLoopResume

Description

DLDP/4/DETECTUNIDIRECT(t): OID [oid] The port is detected exit Loop status. (IfIndex=[integer], IfName=[STRING])

The loop on an interface has been removed or the interface was shut down.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.173.3.4 Warning equipmentAlarm(5)

Parameters

Name Meaning
[oid] Indicates the MIB object ID of the alarm.
IfIndex Indicates the index of the interface where the alarm is generated.
IfName Indicates the name of the interface where the alarm is generated.

Impact on the System

The loop on the interface has been removed.

  • If the fibers on the interface are connected correctly and the loop is removed, services on the interface are resumed.
  • If the interface is shut down, the interface cannot work.

Possible Causes

Cause 1: The fibers on the interface were connected correctly and the loop was removed.

Cause 2: The interface was shut down.

Procedure

  1. Run the display dldp command to check the DLDP status on the interface.

    • If the DLDP port state field displays advertisement, the loop has been removed and no further action is required.

    • If the DLDP port state field displays inactive, go to step 2.

  2. Check whether the interface is in Down state.

    • If so, connect the fibers correctly. When the interface goes Up, go to step 1.
    • If not, contact technical support personnel.