Alarm Handling

S9300, S9300E, and S9300X V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
EOAM_Y1731_1.3.6.1.4.1.2011.5.25.136.1.6.30 hwY1731AisDefectAlarm

EOAM_Y1731_1.3.6.1.4.1.2011.5.25.136.1.6.30 hwY1731AisDefectAlarm

Description

EOAM_Y1731/4/AISDEFECTALARM: OID [OID] MEP enters AIS defect condition. (MdIndex=[INTEGER], MaIndex=[INTEGER], MdName=[STRING], MaName=[STRING], MepID=[INTEGER])

An MEP received an AIS PDU and entered the faulty state.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.136.1.6.30 Warning qualityOfServiceAlarm (3)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

MdIndex

MD index

MaIndex

MA index

MdName

Name of an MD

MaName

Name of an MA

MepId

MEP ID

Impact on the System

Service instances bound to the MA to which the MEP belongs is unavailable.

Possible Causes

The MEP received an AIS PDU carrying an MD level lower than the level of the MD to which the MEP belongs.

Procedure

  1. Check whether a fault occurs in an MA with the lower MD level.

    Run the display cfm remote-mep command to view the value of the CFM Status field.
    • If the value of the CFM Status field is Down, an MA fails. Rectify the fault.
    • If the value of the CFM Status field is Up, go to step 3.

  2. Collect alarm information and configuration information, and then contact technical support personnel.
  3. End.

Related Information