Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
BASETRAP_1.3.6.1.4.1.2011.5.25.129.2.3.1 hwPowerOff

BASETRAP_1.3.6.1.4.1.2011.5.25.129.2.3.1 hwPowerOff

Description

BASETRAP/1/POWEROFF: OID [oid] The power supply is off. (Index=[INTEGER], Severity=[INTEGER], ProbableCause=[INTEGER], EventType=[INTEGER], ContainedIn=[INTEGER], PhysicalName="[OCTET]")

The power module is powered off.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.129.2.3.1 Critical equipmentAlarm(5)

Parameters

Name Meaning

[oid]

Indicates the ID of the MIB object.

Index

Indicates the index of the entity. The entity in the alarm is a power module.

Severity

Indicates the severity level of the alarm.

ProbableCause

Indicates the possible cause of the alarm. The code of the possible cause is as follows:

78: IANAITUPROBABLECAUSE_POWERSUPPLYFAILURE indicates that the power module fails.

EventType

Indicates the alarm type:

  • communicationsAlarm (2): alarm for communication problems
  • qualityOfServiceAlarm (3): alarm for service quality
  • processingErrorAlarm (4): alarm for processing errors
  • equipmentAlarm (5): alarm for the equipment
  • environmentalAlarm (6): alarm for the environment

This alarm is of the equipmentAlarm type, that is, the alarm for the equipment.

ContainedIn

Indicates the index of the parent entity of the alarm entity. In the alarm, this parameter indicates the index of the slot where the power module is located.

PhysicalName

Indicates the name of the entity. In the alarm, this parameter indicates a power supply board.

Impact on the System

Services are affected if there is a backup power module.

Possible Causes

Cause 1:

The power module is powered off manually.

Cause 2:

The power module is powered off because of natural factors. For example, the power module is loose.

Cause 3:

The power module is faulty.

Procedure

  1. Check whether the power module is powered off manually for routine maintenance.

    • If so, the alarm handling ends.
    • If not, go to step 2.

  2. Check whether the power switch on the power module is turned on.

    • If so, go to step 4.
    • If not, go to step 3.

  3. Turn on the power switch, and then check whether a power-on alarm is generated.

    • If so, the alarm handling ends.
    • If not, go to step 4.

  4. If the DC power module is used, check whether the power cable is loose.

    • If so, go to step 5.
    • If not, go to step 6.

  5. Connect the DC power module properly, and then check whether a power-on alarm is generated.

    • If so, the alarm handling ends.
    • If not, go to step 6.

  6. Check whether the hardware of the power module is faulty.

    Method: Replace this power module with a normal power module to check whether a power-on alarm is generated.

    • If so, go to step 7.
    • If not, collect alarm information and configuration information, and then contact technical support personnel.

  7. Replace this power module, and then check whether a power-on alarm is generated.

    • If so, the alarm handling ends.
    • If not, collect alarm information and configuration information, and then contact technical support personnel.