Alarm Handling

S9300, S9300E, and S9300X V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
L2IFPPI_1.3.6.1.4.1.2011.5.25.219.2.2.13 hwBoardPowerOff

L2IFPPI_1.3.6.1.4.1.2011.5.25.219.2.2.13 hwBoardPowerOff

Description

L2IFPPI/4/BOARDPOWEROFF:OID [oid] The LPU is powered off. This LPU only supports the trunks with index 127 or smaller than 127. Delete the trunks with index larger than 127 and power on the LPU.(Index=[INTEGER1], EntityPhysicalIndex=[INTEGER2], PhysicalName=[OCTET], EntityTrapEntType=[INTEGER3], EntityTrapFaultID=[INTEGER4]).

The card was powered off. The card supports only the Eth-Trunk with the index smaller than or equal to 127. Delete the Eth-Trunk with the index larger than 127, and power on the card.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.219.2.2.13 Warning environmentalAlarm(6)

Parameters

Name Meaning
oid Indicates the ID of a MIB object.
OCTET Indicates the entity name.
INTEGER1 Indicates the instance index.
INTEGER2 Indicates the index of the physical entity.
INTEGER3 Indicates the entity type.
INTEGER4 Indicates the error code.

Impact on the System

The card cannot be registered.

Possible Causes

Only some cards support Eth-Trunk specification extension. If Eth-Trunk specification extension is configured and there is an Eth-Trunk with the index larger than 127, when you install the card that does not support Eth-Trunk specification (low-specification card), the low-specification card cannot be registered.

Procedure

  1. Use either of the following methods:

    • Remove the low-specification card. For details about the supported cards, see the assign trunk command.
    • If the low-specification card must be used, delete the Eth-Trunk with the index larger than 127. For details about the mapping between Eth-Trunk indexes and IDs, see the display trunk index-map command.

  2. If the alarm is not cleared, contact technical support personnel.

Related Information

None