Alarm Handling

S9300, S9300E, and S9300X V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
MPLS_1.3.6.1.4.1.2011.5.25.227.2.1.25 hwBoardMplsFwdResLack

MPLS_1.3.6.1.4.1.2011.5.25.227.2.1.25 hwBoardMplsFwdResLack

Description

MPLS/4/MPLS_LACK:OID [OID] The MPLS resource usage has reached or exceeded [GAUGE1]%. (EntPhysicalindex=[GAUGE2],Slot=[OCTET],ResourceType=[INTEGER])

The usage of MPLS forwarding entries reached or exceeded the upper threshold.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.227.2.1.25

Warning

equipmentAlarm(5)

Parameters

Name Meaning
OID Indicates the MIB object ID of the alarm.
GAUGE1 Indicates the upper threshold of an alarm.
EntPhysicalindex Indicates the physical entity index.
Slot Indicates the slot ID.
ResourceType Indicates a resource type.
  • 330: sourceVpTable (VP and SVP entries)
  • 331: mplsEntryTable (MPLS_ENTRY and INSEGMENT entries)
  • 332: mplsVcAndSwapLabelTable (VC_AND_SWAP entries)
  • 333: ipTunnelMplsTable (EGR_IP_TUNNEL_MPLS and TUNNEL entries)

Impact on the System

When the usage of MPLS forwarding entries reaches 100%, the MPLS service cannot be normally transmitted.

Possible Causes

The usage of MPLS forwarding entries reached or exceeded the upper threshold.

Procedure

  1. Run the display current-configuration command to check detailed device configuration. Delete unnecessary service configuration based on the value of ResourceType in the alarm information.

    • If the value of ResourceType is 330 or 331, check whether the configuration of VPLS, VLL, or PWE3 is redundant.
    • If the value of ResourceType is 332, check whether the configuration of VPLS, VLL, PWE3, L3VPN, MPLS LDP, or MPLS TE is redundant.
    • If the value of ResourceType is 333, check whether the configuration of MPLS LDP or MPLS TE is redundant.
    • If the value of ResourceType is 578, check whether the configuration of VPLS is redundant.

  2. Check whether the alarm is cleared. If not, go to step 3.
  3. Collect alarm information and configuration information, and then contact technical support personnel.

Related Information