Alarm Handling

S9300, S9300E, and S9300X V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
BASETRAP_1.3.6.1.4.1.2011.5.25.129.2.1.2 hwEntityInert

BASETRAP_1.3.6.1.4.1.2011.5.25.129.2.1.2 hwEntityInert

Description

BASETRAP/4/ENTITYINSERT: OID [oid] Physical entity is inserted. (Index=[INTEGER], Severity=[INTEGER], ProbableCause=[INTEGER], EventType=[INTEGER], ContainedIn=[INTEGER], PhysicalName="[OCTET]")

This alarm is generated when a physical entity, such as a board, power module, or fan, is installed.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.129.2.1.2 Warning equipmentAlarm (5)

Parameters

Name Meaning
[oid] Indicates the ID of the MIB object.
Index Indicates the index of the entity, such as the board, power module, fan, or subcard.
Severity Indicates the severity level of the alarm.
ProbableCause Indicates the possible causes of the alarm. The codes of the possible causes are as follows:

1024: IANAITUPROBABLECAUSE_OTHER indicates that the causes are unknown.

EventType Indicates the alarm type. Alarms are classified into the following types:
  • communicationsAlarm (2)
  • qualityOfServiceAlarm (3)
  • processingErrorAlarm (4)
  • equipmentAlarm (5)
  • environmentalAlarm (6)

This alarm is an alarm of the equipmentAlarm type, that is, the alarm on device errors.

ContainedIn Indicates the parent index of the entity where the alarm is generated.

1. If the entity is a board, fan, or power module, the parent index is the index of the slot where the board, fan, or power module is located.

2. If the entity is a subcard, the parent index is the index of the slot where the subcard is located on the board.

PhysicalName Indicates the physical name of the entity where the alarm is generated. For example, the physical name of an LPU is LE01G48SC.

Impact on the System

None.

Possible Causes

An entity is installed.

Procedure

  1. This is a normal notification and no action is required.