Alarm Handling

S9300, S9300E, and S9300X V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
BASETRAP_1.3.6.1.4.1.2011.5.25.129.2.3.2 hwPowerOn

BASETRAP_1.3.6.1.4.1.2011.5.25.129.2.3.2 hwPowerOn

Description

BASETRAP/4/POWERON: OID [oid] The power supply is on. (Index=[INTEGER], Severity=[INTEGER], ProbableCause=[INTEGER], EventType=[INTEGER], ContainedIn=[INTEGER], PhysicalName="[OCTET]")

This recovery notification is generated when the power module is switched on.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.129.2.3.2 Warning equipmentAlarm(5)

Parameters

Name Meaning
[oid] Indicates the ID of the MIB object.
Index Indicates the index of the entity. The entity in an alarm on power supply is a power supply board.
Severity Indicates the severity level of the alarm.
ProbableCause Indicates the possible causes of the alarm. The codes of the possible causes are as follows:

1024: IANAITUPROBABLECAUSE_OTHER indicates that the causes are unknown.

EventType Indicates the alarm type. Alarms are classified into the following types:
  • communicationsAlarm (2)
  • qualityOfServiceAlarm (3)
  • processingErrorAlarm (4)
  • equipmentAlarm (5)
  • environmentalAlarm (6)

This alarm is an alarm of the equipmentAlarm type.

ContainedIn Indicates the index of the parent entity of the alarm entity. In the alarm message, this parameter indicates the index of the slot where the power supply is located.
PhysicalName Indicates the name of the entity. In the alarm message, this parameter indicates a power supply board.

Impact on the System

None.

Possible Causes

Cause 1

The power module is switched on.

Cause 2

The fault on the power module is rectified.

Procedure

  1. This is a normal notification and no action is required.