Alarm Handling

S9300, S9300E, and S9300X V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ETRUNK_1.3.6.1.4.1.2011.5.25.178.2.2 hwETrunkMemberStatusChange

ETRUNK_1.3.6.1.4.1.2011.5.25.178.2.2 hwETrunkMemberStatusChange

Description

ETRUNK/4/TRAP_MEMBER_STATUS:OID [oid] The status of an E-Trunk member changed. (E-Trunk ID=[integer], Member type=[integer], Member ID=[integer], Member status=[integer], Status reason=[integer])

The status change of an E-Trunk member was advertised to the NMS.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.178.2.2 Warning equipmentAlarm(5)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

E-Trunk ID

ID of the E-Trunk to which the E-Trunk member belongs

Member type

Type of E-Trunk member. There is only one member type: Eth-Trunk.

Member ID

ID of the E-Trunk member

Member status

Status of the E-Trunk member

Status reason

Cause for the E-Trunk member in such a status

Impact on the System

If the local E-Trunk member is the master, the E-Trunk member can forward data.

If the local E-Trunk member is the backup, the E-Trunk member cannot forward data.

Possible Causes

1.

The status of the E-Trunk to which the local E-Trunk member belongs was changed.

2.

The peer of the E-Trunk member was faulty or recovered from a fault.

3.

The operating mode of the local E-Trunk member is changed.

Procedure

  1. Run the display e-trunk etrunk-id command to check whether the master/backup status is changed on the local end of the E-Trunk.

  2. Check whether the operating mode of the local E-Trunk member is changed.

    • If so, go to Step 5.

    • If not, go to Step 3.

  3. Check whether the E-Trunk interface is shut down.

    • If so, go to Step 7.

    • If not, go to Step 4.

  4. Check whether the physical links are repaired, and the trap is cleared.

    • If so, go to Step 9.

    • If not, go to Step 8.

  5. Check whether the operating mode of the local E-Trunk member is changed according to a legal requirement.

    • If so, go to Step 9.

    • If not, go to Step 8.

  6. Run the e-trunk mode { auto |force-master | force-backup } command in the Eth-Trunk interface view to correctly configure the operating mode of the Eth-Trunk in the E-Trunk according to the networking requirement. Then, check whether the trap is cleared.

    • If so, go to Step 9.

    • If not, go to Step 8.

  7. Run the undo shutdown command in the interface view to check whether the trap is cleared.

    • If so, go to Step 9.

    • If not, go to Step 4.

  8. Collect alarm information and configuration information, and then contact technical support personnel.
  9. End.