Alarm Handling

S9300, S9300E, and S9300X V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
EOAM1AG_1.3.6.1.4.1.2011.5.25.136.1.6.46 hwDot1agCfmRDI

EOAM1AG_1.3.6.1.4.1.2011.5.25.136.1.6.46 hwDot1agCfmRDI

Description

EOAM1AG/3/RDI: OID [oid] MEP received a CCM with RDI flag set. (MdIndex=[GAUGE], MaIndex=[GAUGE], MdName=[STRING], MaName=[STRING], MepId=[INTEGER], RmepId=[INTEGER])

The RMEP sent a CCM carrying the RDI flag with the value of 1 to the MEP.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.136.1.6.46 Minor communicationsAlarm(2)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

MdIndex

Index of an MD table

MaIndex

Index of an MA table

MdName

Name of an MD

MaName

Name of an MA

MepId

ID of a MEP

RmepId

ID of an RMEP

Impact on the System

System performance will not be affected.

Possible Causes

Cause 1: If an RMEP received a non-RDI trap, the RMEP set the RDI flag to 1 in a CCM and sent the CCM to the MEP.

Cause 2: If CFM association was enabled and an associated interface or protocol notified the RMEP of a detected fault, the RMEP set the RDI flag to 1 in a CCM and sent the CCM to the MEP.

Procedure

  1. Run the display cfm remote-mep [ md md-name ma ma-name mep-id mep-id ] command on the RMEP to view the value of the Alarm Status field.

    • If the value of the Alarm Status field is none, go to Step 3.

    • If the value of the Alarm Status field is not none, go to Step 2.

  2. Perform the following steps on the RMEP:

  3. Perform the following steps on the RMEP:
    1. Run the oam-mgr command to enter the MGR view.
    2. Run the display this command. Check whether CFM is associated with an interface or a protocol. If there is no association configuration, go to 4.
    3. If CFM is associated with an interface or a protocol, check whether the associated interface or protocol fails. If the associated interface or protocol works properly, go to Step 4. If the associated interface or protocol fails, rectify the fault. Check whether the trap is cleared. If the trap persists, go to Step 4.
  4. Collect alarm information and configuration information, and then contact technical support personnel.