Log Reference

S9300, S9300E, and S9300X V200R010C00

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
BFD/4/IO_REACH_SESSLMT

BFD/4/IO_REACH_SESSLMT

Message

BFD/4/IO_REACH_SESSLMT:The number of sessions on the slot had reached upper limit, new session bound on this interface board could not be created! (SlotNumber=[STRING])

Description

The number of sessions bound to an interface reached the upper limit. No more sessions bound to the interface can be created.

Parameters

Parameter Name Parameter Meaning

SlotNumber

indicates the number of an interface board.

Possible Causes

The number of sessions bound to an interface reached the upper limit. No more sessions bound to the interface can be created.

Procedure

  1. Run the display bfd statistics command to view BFD session information.
  2. Do not create more sessions bound to the interface on the interface board. Alternatively, delete some useless sessions bound to the interface on the interface board.
Translation