Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
CLOCK/4/TS_ABNORMAL

CLOCK/4/TS_ABNORMAL

Message

CLOCK/4/TS_ABNORMAL:The timestamp is abnormal. (MaxPD1588=[LONG], MinPD1588=[LONG])

Description

Transient occurs in the time stamp received from the upstream device. The maximum phase discrimination is greater than 30 or the minimum phase discrimination is smaller than -30. The log records the maximum phase discrimination and the minimum phase discrimination.

Parameters

Parameter Name Parameter Meaning

[LONG]

Indicates the maximum value of phase discrimination.

[LONG]

Indicates the minimum value of phase discrimination.

Possible Causes

1. Generally, jitter occurs during the switchover of clock source. This log is generated when the jitter occurs.

2. The performance of the traced clock source degrades, for example, the time jitter occurs.

Procedure

  • If the clock source is switched, this is a normal situation.
  • If the clock source of the upstream device is switched, this is a normal situation.
  • After the clock source is switched, if the log is generated on all the interfaces of the local device, the clock board of the local device may be faulty. Then perform an active/standby switchover. If the log does not occur, the original active clock board is faulty. You can replace the clock board.
  • Record this log message and contact technical support personnel.