No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Log Reference

S9300, S9300E, and S9300X V200R010C00

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
IPV6FIBAGENT/4/SENDPLYSLOT6

IPV6FIBAGENT/4/SENDPLYSLOT6

Message

IPV6FIBAGENT/4/SENDPLYSLOT6:FIB6 failed to send a policy to slot [slot-number].

Description

FIB6 failed to send a policy-change message to the interface board.

Parameters

Parameter Name Parameter Meaning
[slot-number] indicates the slot number of an interface board.

Possible Causes

The main control board failed to send a policy-change message to the interface board during hot plugging.

Procedure

  1. Run the display fib-policy slot [ slot-number ] command to view of FIB policies on the interface board and save the output of this command.
  2. Collect log information and configuration information, and then contact technical support personnel.