Log Reference

S9300, S9300E, and S9300X V200R010C00

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ADA_BFD/3/IPCSENDFAIL

ADA_BFD/3/IPCSENDFAIL

Message

ADA_BFD/3/IPCSENDFAIL:Failed to send IPC message to IO board([STRING])(Error Code:[ULONG])!

Description

The main control board failed to send IPC messages to the interface board.

Parameters

Parameter Name Parameter Meaning
[STRING] Indicates the slot ID of the interface board.
[ULONG] Indicates the error code.

Possible Causes

The main control board failed to send IPC messages to the interface board.

Procedure

  1. Ensure that the interface board has registered.
  2. View the IPC-related logs to check whether an IPC message sending failure log is recorded on the interface board. If the log exists on the interface board, contact technical support personnel.