Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
OSPF/4/INTF_NSR_OVERTIME_LIMIT

OSPF/4/INTF_NSR_OVERTIME_LIMIT

Message

OSPF/4/INTF_NSR_OVERTIME_LIMIT: The interface go on process, as slave's ack didn't come for [ULONG] seconds. (IfName=[STRING1], IpAddr=[IPADDR], ProcessId=[USHORT], AreaId=[STRING2])

Description

If the OSPF interface on the active board receives no response from the standby board within a specified interval, the active board considers that the standby board has responded and does not require retransmission of backup messages.

Parameters

Parameter Name Parameter Meaning
[ULONG] Total time that the interface waits for the response from the standby board, in seconds
IfName Interface name
IpAddr IP address of the interface
ProcessId Process ID to which the interface belongs
AreaId Area ID to which the interface belongs

Possible Causes

After the OSPF interface on the active board initiates a handshake with the standby board, the interface waits for a response from the standby board. If the total waiting time exceeds the upper limit (equal to or less than 600 seconds, generally 40 times of the retransmission interval), it may be caused by inconsistent OSPF interface statuses on the active board and the standby board, blocked backup channel, or loss of backup messages.

Procedure

  1. Run the display ospf interface command to check whether the statuses of OSPF interfaces on the active board and the standby board are consistent.

    • If they are consistent, ignore this log message.