Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
MPLS/4/MPLS_PHP_RESLACK

MPLS/4/MPLS_PHP_RESLACK

Message

MPLS/4/MPLS_PHP_RESLACK: [STRING]

Description

The device failed to deliver PHP-related ACLs because ACL resources are insufficient.

Parameters

Parameter Name Parameter Meaning
STRING Displays why the PHP-incapable device failed to deliver PHP-related ACLs.

Possible Causes

The number of labels of the PHP type exceeds the upper limit on the device.

Procedure

  1. Run the label advertise { explicit-null | non-null } command in the MPLS view of the switch directly connected to the local device to enable the egress switch to distribute a label without an explicit null label to the PHP node.
  2. Run the reset mpls ldp command in the user view of the local device to reset LDP globally.