No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Log Reference

S9300, S9300E, and S9300X V200R010C00

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALML/4/POWER_LACK

ALML/4/POWER_LACK

Message

ALML/4/POWER_LACK:[STRING] cannot be powered on due to lack of power.(rating = [ULONG1](W), remain = [ULONG2](W))

Description

The power supply does not have enough power to power on boards.

Parameters

Parameter Name Parameter Meaning
[STRING] Entity name
[ULONG1] Rated power of a board
[ULONG2] Remaining power of the system

Possible Causes

The power supply does not have enough power to power on boards.

Procedure

  1. Check whether the tab of the power cable locking strap is incorrectly inserted into an air vent of the power module panel. If so, the power supply cannot work properly. You need to remove the tab from the air vent. If the log persists, go to the next step.
  2. Run the display device command in any view. If the Register field of the power supply displays Unregistered, this power supply fails to register. To ensure that the power supply registers successfully (that is, the Register field displays Registered), perform any of the following operations: remove and then install the power supply, remove and then install the monitoring unit, or replace the power supply. If the log persists, go to the next step.
  3. Increase the number of power supplies to improve the power. If the number of power supplies has reached the maximum value, replace the power supply with one providing higher power. If the log persists, go to the next step.
  4. Contact technical support personnel.
Translation
Download
Updated: 2019-08-21

Document ID: EDOC1000142069

Views: 574473

Downloads: 37

Average rating:
This Document Applies to these Products
Related Version
Related Documents
Share
Previous Next