Log Reference

S9300, S9300E, and S9300X V200R010C00

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
FMES/6/FMES_LOG

FMES/6/FMES_LOG

Message

FMES/6/FMES_LOG:Input packets are discarded for CRC. (Slot=[ULONG1]/[ULONG2], UnitID=[ULONG3], PortID=[STRING1], DiscardNumber=[STRING2])

Description

CRC errors occur on the HG channel of the board.

Parameters

Parameter Name Parameter Meaning
[ULONG1] Indicates the chassis ID of the board.
[ULONG2] Indicates the slot ID of the board.
[ULONG3] Indicates the chip ID.
[STRING1] Indicates the port number of the HG channel.
[STRING2] Indicates the number of CRC error packets.

Possible Causes

The number of packets discarded because CRC check failed exceeded the threshold. Possible causes are as follows:

  • 1. The board is not properly installed.
  • 2. The plug-in connected to the board has bent pins.
  • 3. The slot on the backplane has bent pins.
  • 4. The board is faulty.

Procedure

  1. Check whether the front panel of the board is securely tightened.
    • If so, go to step 2.
    • If not, ensure that it is securely tightened.
  2. Restart the board and check whether the log persists.
    • If so, go to step 3.
    • If not, the alarm handling ends.
  3. Remove the board and check whether there are bent pins on the backplane and connector.
    • If so, go to step 4.
    • If not, go to step 5.
  4. Replace the board and check whether the log persists.
    • If so, go to step 6.
    • If not, the alarm handling ends.
  5. Remove and then install the board and check whether the log persists.
    • If so, go to step 6.
    • If not, the alarm handling ends.
  6. Collect log information and configuration information, and then contact technical support personnel.You can collect diagnostic information using the display diagnostic-information command.