Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ISIS/3/REA_MAX_SEQ_NUM

ISIS/3/REA_MAX_SEQ_NUM

Message

ISIS/3/REA_MAX_SEQ_NUM: The LSP sequence number almost reaches the maximum value. (isisSysInstance=[USHORT], isisSysLevelIndex=[USHORT], isisPduLspId=[STRING])

Description

The LSP sequence number reached the maximum value.

Parameters

Parameter Name Parameter Meaning

isisSysInstance

ID of an IS-IS process

isisSysLevelIndex

IS-IS level

isisPduLspId

LSP ID

Possible Causes

Cause 1: The sequence numbers increase to the maximum value as expected.

Cause 2: An attacker simulated a locally generated LSP, set its sequence number to the maximum value, and sent the LSP to the local device.

Cause 3: Another device on the network had the same IS-IS System ID as the local one.

Procedure

  1. Run the display isis lsdb command to check the sequence numbers of locally generated LSPs.

    • If the sequence numbers increase as expected, no action is required.
    • If the sequence numbers increase too fast, go to Step 2.

  2. Run the timer lsp-refresh command in the IS-IS view to increase the LSP update interval and then run the display isis lsdb command to check the sequence numbers of locally generated LSPs.

    • If the sequence numbers increase as expected, go to Step 5.
    • If the sequence numbers increase too fast, go to Step 3.

  3. Check whether there is another device on the network with the local IS-IS System ID.

    • If such a device exists, change its system ID.
    • If no such a device exists, go to Step 4.

  4. Collect alarm information and configuration information, and then contact technical support personnel.
  5. End.