No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Log Reference

S9300, S9300E, and S9300X V200R010C00

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
MD/4/BND_MTI

MD/4/BND_MTI

Message

MD/4/BND_MTI:In VPN instance "[vpn-instance-name]", failed to bind MTI [interface-name]. (FlCode=[STRING][ULONG])

Description

Failed to bind the MTI to the instance.

Parameters

Parameter Name Parameter Meaning
[vpn-instance-name] Indicates the name of a VPN instance.
[interface-name] Indicates the name of an interface.
FlCode Indicates the name of the source code file and the line number of this log message.

Possible Causes

The physical interface changed.

Procedure

  1. Run the multicast-domain share-group group-address binding mtunnel number command to re-configure a physical interface.