Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALML/4/VOLT_UPPER

ALML/4/VOLT_UPPER

Message

ALML/4/VOLT_UPPER:The "[STRING1]" voltage of sensor [STRING2](entity) exceeds the upper [STRING3] limit.(SensorNum=[ULONG], Value=[STRING4], UpperThreshold=[STRING5], LowerThreshold=[STRING6])

Description

The voltage sensor detects that the voltage exceeds the upper limit.

Parameters

Parameter Name Parameter Meaning
[STRING1] Name of voltage sensor
[STRING2] Entity name
[STRING3] Alarm level
[ULONG] Sensor No.
[STRING4] Current voltage value
[STRING5] Upper limit of voltage
[STRING6] Lower limit of voltage

Possible Causes

The voltage sensor detects that the voltage exceeds the upper limit.

Procedure

  1. Check whether any power module fails.
    • If so, go to step 2.
    • If not, go to step 3.
  2. Ensure that other power modules operate normally and replace the abnormal power module.
  3. Run the display voltage slot slot-id command to check whether the voltage of the board for which an alarm is generated is normal.
    • If not, replace this board and go to step 4.
    • If so, go to step 6.
  4. Check whether the alarm is cleared.
    • If so, the alarm handling ends.
    • If not, collect log information and configuration information, and then contact technical support personnel.You can collect diagnostic information using the display diagnostic-information command.