No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Log Reference

S9300, S9300E, and S9300X V200R010C00

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
CLOCK/4/TIME_ADJUST

CLOCK/4/TIME_ADJUST

Message

CLOCK/4/TIME_ADJUST:The time is adjusted. (DistinctAdjustCount=[ULONG], TinyAdjustCount=[ULONG])

Description

The clock board can perform distinct adjustment or fine tune on internal clock. This log is generated only when the clock board performs distinct adjustment. The log records the counts of distinct adjustment and fine tune.

Parameters

Parameter Name Parameter Meaning

[ULONG]

Indicates the distinct adjustment count.

[ULONG]

Indicates the tiny adjustment count.

Possible Causes

1. Generally, jitter occurs during the switchover of clock source. This log is generated when the jitter occurs.

2. The performance of the traced clock source degrades, for example, the time jitter occurs.

Procedure

  • If the clock source is switched, this is a normal situation.
  • If the clock source of the upstream device is switched, this is a normal situation.
  • After the clock source is switched, if the log is generated on all the interfaces of the local device, the clock board of the local device may be faulty. Then perform an active/standby switchover. If the log does not occur, the original active clock board is faulty. You can replace the clock board.
  • Record this log message and contact technical support personnel.
Translation
Download
Updated: 2019-08-21

Document ID: EDOC1000142069

Views: 574446

Downloads: 37

Average rating:
This Document Applies to these Products
Related Version
Related Documents
Share
Previous Next