Log Reference

S9300, S9300E, and S9300X V200R010C00

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
RIPNG/3/NO_GLO_SITE_ADDR_F

RIPNG/3/NO_GLO_SITE_ADDR_F

Message

RIPNG/3/NO_GLO_SITE_ADDR_F:Specific request is dropped, because global or site-local address is not assigned for interface [interface-name]. (ProcessId=[ULONG])

Description

The request of RIPng is dropped because there was no global or site-local address assigned for interface.

Parameters

Parameter Name Parameter Meaning
[interface-name] Indicates the interface name.
ProcessId Indicates the process ID.

Possible Causes

If an Update packet was sent to a non-RIPng interface, the global address or the local address was considered as the source address.

Procedure

  1. Configure a global address or a local address on the interface.