Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALML/4/R1R2_SYN_START

ALML/4/R1R2_SYN_START

Message

ALML/4/R1R2_SYN_START:A board with version earlier than V1R3 is inserted into slot [STRING]. Version synchronization requires about 10 minutes. Do not reset, remove, or power off the board during the version upgrade.

Description

After a board with a version earlier than V100R003 is used as the standby main control board of a V100R006 device, the board starts version upgrade.

Parameters

Parameter Name Parameter Meaning
[ULONG] Specifies the slot ID.

Possible Causes

A board with a version earlier than V100R003 is used as the standby main control board of a V100R006 device.

Procedure

  • Wait until the upgrade is completed. Do not reset, remove, or power off the board during the upgrade.