Log Reference

S9300, S9300E, and S9300X V200R010C00

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ADDR/4/COLLISION_CNT_EXCEED

ADDR/4/COLLISION_CNT_EXCEED

Message

ADDR/4/COLLISION_CNT_EXCEED: Collision count reached maximum value for IPv6 CGA address [ip-address] on interface [interface-name].

Description

The number of CGA IPv6 address collisions exceeded the maximum number allowed by an interface.

Parameters

Parameter Name Parameter Meaning
ip-address IPv6 CGA Address.
interface-name Interface Name of the CGA address.

Possible Causes

The same IPv6 CGA address was configured on an interface. The maximum number of address collisions allowed by the interface (2) was exceeded.

Procedure

  1. The administrator should re-configure the CGA address with different prefix.