Log Reference

S9300, S9300E, and S9300X V200R010C00

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
CSPF/3/IGP_NWLSA_INFONULL

CSPF/3/IGP_NWLSA_INFONULL

Message

CSPF/3/IGP_NWLSA_INFONULL: Received a Network-LSA with null information from IGP [IgpName].

Description

A network-LSA event that did not contain any network-LSA information was received from the IGP protocol.

Parameters

Parameter Name Parameter Meaning
[IgpName] Indicates the name of an IGP protocol, such as IS-IS and OSPF.

Possible Causes

Network LSA event does not contain any network lsa information.

Procedure

  1. 1. Verify IGP database.

    • If IGP is OSPF use display ospf lsdb opaque-link and display ospf lsdb opaque-area command.

    • If IGP is ISIS use display isis traffic-eng link and display isis traffic-eng network command.

  2. 2. Reset OSPF or IS-IS process.
Translation