No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Log Reference

S9300, S9300E, and S9300X V200R010C00

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
NSADP/4/NS_ID_CREATEFAIL

NSADP/4/NS_ID_CREATEFAIL

Message

NSADP/4/NS_ID_CREATEFAIL: Netstream Fails to create streams in slot [slot-id]. (Failed input stream count=[STRING], failed output stream count=[STRING])

Description

NetStream flows failed to be created.

Parameters

Parameter Name Parameter Meaning
slot-id Indicates the slot ID.
Failed input stream count Indicates the number of inbound NetStream flows that failed to be created.
failed output stream count Indicates the number of outbound NetStream flows that failed to be created.

Possible Causes

The number of NetStream flows reached the maximum that can be created. As a result, NetStream flows failed to be created.

Procedure

  1. Run the display netstream all command to check the NetStream configuration on a device. If ip netstream inbound or ip netstream outbound exists on an interface, the NetStream configuration has been configured on this interface.
  2. Method 1: On the interface that has the NetStream function configured, run the ip netstream sampler fix-packets packet-interval { inbound | outbound } command to increase the NetStream sampling rate. Check whether the device still prints this log.

    Method 2: On the interface that has the NetStream function configured, configure IPv4 flexible NetStream flow statistics collection and apply a flexible flow statistics template on the interface. Check whether the device still prints this log.

    • If so, go to step 3.
    • If not, no further action is required.

  3. Collect log information and configuration information, and then contact technical support personnel.You can collect diagnostic information using the display diagnostic-information command.
Translation
Download
Updated: 2019-08-21

Document ID: EDOC1000142069

Views: 548362

Downloads: 37

Average rating:
This Document Applies to these Products
Related Version
Related Documents
Share
Previous Next