Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
CLOCK/4/TS_NOT_CHG

CLOCK/4/TS_NOT_CHG

Message

CLOCK/4/TS_NOT_CHG:The timestamp is not changed. (T1Count=[ULONG], T2Count=[ULONG])

Description

T1 time stamp or T2 time stamp received from the upstream device is not changed. The log records the number of times T1 and T2 time stamps are not changed.

Parameters

Parameter Name Parameter Meaning

[ULONG]

Indicates the number of unchanged T1 time stamps.

[ULONG]

Indicates the number of unchanged T2 time stamps.

Possible Causes

1. An error occurs on the upstream interface that transmits signal. As a result, the time stamps are not updated.

2. The channel for receiving time stamps on the clock source is closed. As a result, the clock source cannot receive the updated time stamps.

Procedure

  1. Run the clock force-switch command to change the clock source and then check whether this log is generated on all interfaces of the local device.
    • If so, the clock board of the local device is faulty. Perform an active/standby switchover of clock boards and go to step 2.
    • If not, go to step 3.
  2. Check whether this log persists.
    • If so, go to step 3.
    • If not, the alarm handling ends.
  3. Collect log information and configuration information, and then contact technical support personnel.You can collect diagnostic information using the display diagnostic-information command.