Log Reference

S9300, S9300E, and S9300X V200R010C00

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
CLOCK/4/STOP_SLOT_SRC

CLOCK/4/STOP_SLOT_SRC

Message

CLOCK/4/STOP_SLOT_SRC:The slot [ULONG] stops delivering clock signal to the clock board.

Description

During clock source selection in a frame, a slot stops sending clock signals.

Parameters

Parameter Name Parameter Meaning

[ULONG]

Specifies the slot ID.

Possible Causes

1. The clock source is switched to another slot according to the source selection rule.

2. The frame priority of the interface is deleted.

3. The interface becomes Down.

4. The interface is a 1000M electrical interface.

5. The interface is configured with loopback.

Procedure

  • If the clock source is switched to another slot in the same frame, the log is normal.
  • If the log is generated in other cases, do as follows:
    1. Run the display interface interface-type interface-number command to check whether the interface is in Down state. If so, rectify the fault to ensure that the interface is Up.
    2. Run the display interface interface-type interface-number command to check whether the interface is a 1000M electrical interface. The 1000M electrical interface does not support Ethernet synchronization. Do not use this type of interface.
    3. Check whether the loopback internal command is configured on the interface. If so, cancel the configuration.
    4. Check whether the interface has the frame priority configured using the clock { left-frame | right-frame } priority command. If not, configure the frame priority for it.
    5. If the preceding information is correct, Collect log information and configuration information, and then contact technical support personnel.You can collect diagnostic information using the display diagnostic-information command.
Translation
Download
Updated: 2019-08-21