Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
SECE/4/STORMCTRL_IF_ERROR_DOWN

SECE/4/STORMCTRL_IF_ERROR_DOWN

Message

SECE/4/STORMCTRL_IF_ERROR_DOWN:Interface [STRING] is error-down for storm-control.

Description

The storm control function was configured, and a broadcast storm occurred on the interface. As a result, the interface status became Error-Down.

Parameters

Parameter Name Parameter Meaning

[STRING]

Indicates the interface name.

Possible Causes

The storm control function was configured on the interface, and the storm control action was set to error-down. A broadcast storm occurred due to a loop, attack, or hardware fault, and the average rate of broadcast, multicast, or unknown unicast packets exceeded the upper threshold. As a result, the storm control action was performed and the interface status became Error-Down.

Procedure

  1. Check whether the broadcast storm is caused by a loop. If so, remove the loop. For the broadcast storm troubleshooting procedure, see MAC Address Flapping Occurs on a Layer 2 Network and STP Faults Occur in the Revelations of Troublesolving.
  2. Run shutdown and undo shutdown commands in sequence on the interface. If many interfaces are in Error-Down state, run the error-down auto-recovery cause storm-control interval interval-value command in the system view to enable these interfaces to go Up and set a recovery delay. Then run the display error-down recovery command to check whether there are still interfaces in Error-Down state.