Log Reference

S9300, S9300E, and S9300X V200R010C00

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALML/4/HSB_SWITCH_CAUSE

ALML/4/HSB_SWITCH_CAUSE

Message

ALML/4/HSB_SWITCH_CAUSE:[STRING1] causes MPU board[ULONG] to reset. Switch cause code: [STRING2].

Description

This log records reset information of the active MPU.

Parameters

Parameter Name Parameter Meaning
[STRING1] Cause description of active/standby switchover. The specific causes are as follows:
  • Unknown switch reason: unknown reason.
  • VRP command force: forced reset through command line.
  • Master MPU is no memory: The active MPU has insufficient memory.
  • VRP find task deadloop: task infinite loop.
  • Batch was not over: task abnormal.
  • Master switch to slave Interrupt: Active/standby switchover results in reset of the MPU.
  • Ecm Channel was faulty: ECM channel failure.
  • Monitor bus communication Interrupt: CANbus communication interrupted
  • MPU board was pulled out: The MPU is removed.
[ULONG] Slot ID of the active MPU
[STRING2] Cause code of active/standby switchover.
  • 0: unknown reason.
  • 1: forced reset through command line.
  • 2: The active MPU has insufficient memory.
  • 3: task infinite loop
  • 4: task abnormal
  • 5: Active/Standby switchover causes the active MPU to reset.
  • 6: ECM channel failure.
  • 7: CANbus communication interrupted
  • 8: The MPU is removed.

Possible Causes

Reason 1:

Forced reset is performed through the command line.

Reason 2:

The active MPU has insufficient memory.

Reason 3:

Task infinite loop occurs.

Reason 4:

A task is abnormal.

Reason 5:

Active/Standby switchover causes the active MPU to reset.

Reason 6:

An ECM channel fails.

Reason 7:

The communication of the CANbus is interrupted.

Reason 8:

The MPU is removed.

Procedure

  1. Check whether the active MPU is reset for routing maintenance.
    • If so, the alarm handling ends.
    • If not, go to step 2.
  2. Collect log information and configuration information, and then contact technical support personnel.You can collect diagnostic information using the display diagnostic-information command.