Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
OSPF/6/BACKUP_LENGTH_ERR

OSPF/6/BACKUP_LENGTH_ERR

Message

OSPF/6/BACKUP_LENGTH_ERR:The data length was unidentifiable in the restoration process. (Type=[STRING], Length=[USHORT])

Description

During data restoration on the SMB, the length of TLV messages cannot be recognized.

Parameters

Parameter Name Parameter Meaning
Type Indicates the type of the data.
Length Indicates the length of the data.

Possible Causes

The length of TLV messages was inconsistent.

Procedure

  1. Run the display current-configuration ospf command to check whether configurations on the AMB and SMB are the same. If so, go to Step 3; if not, go to Step 2.
  2. If some commands are only used on the AMB, configure them on the SMB.
  3. Contact contact technical support personnel.