Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
DOT1X/5/QUIETTABLE_FULL

DOT1X/5/QUIETTABLE_FULL

Message

DOT1X/5/QUIETTABLE_FULL:The user cannot be authenticated temporarily,because the number of entries in the quiet table exceeds the upper limit.(MAC Address=[STRING])

Description

The silent table is full and the user cannot be authenticated.

Parameters

Parameter Name Parameter Meaning
MAC Address Indicates the MAC address of the user.

Possible Causes

The silent table was full.

Procedure

  1. Check whether the device is attacked by packets. If so, process these attack packets first.
  2. The user can be authenticated after the silent table is aged.
  3. Collect log information and configuration information, and then contact technical support personnel.You can collect diagnostic information using the display diagnostic-information command.