Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Software and Hardware Supporting S12710 Clustering

Software and Hardware Supporting S12710 Clustering

Device Model

S12710

Software Version

V200R010C00 and later versions

License Required

No

CSS Card Slot

CSS cards are integrated into MPUs (ET1D2MPUBC00) and do not need to be installed.

CSS cards are integrated into SFUs (ET1D2SFUB000) and do not need to be installed.

MPU and SFU models are abbreviated to MPUB and SFUB respectively.

Hot Swap

-

Number of CSS cards supported by each chassis

4

Number of CSS ports on each CSS card and bandwidth of a single CSS port

Four 10G ports and one 40G port

Pluggable Modules for Ports on CSS Cards

10G port:
  • 1 m, 3 m, 5 m (passive), and 10 m (active) SFP+ cables

  • SFP+ optical module and fiber

  • 3 m and 10 m SFP+ AOC cables

40G port:
  • 1 m, 3 m, and 5 m QSFP+ high-speed cables
  • QSFP+ optical module (except the QSFP-40G-SR-BD model) and fiber
  • 10 m QSFP+ AOC cable (this cable cannot be used when 40G ports on both ends are split into 10G ports)

Hardware Configuration

  • Only two S12710s can set up a CSS.
  • Each chassis can have only one MPU installed. It is recommended that each chassis have two MPUs installed. If 1+N backup of MPUs is required so that a CSS can operate normally even if two MPUs in one chassis are faulty, SFUs also need to be installed.