No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

S12700 V200R010C00 Configuration Guide - Device Management

This document describes the principles and configurations of the Device Management features, and provides configuration examples of these features.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Setting Optical Power Alarm Thresholds

Setting Optical Power Alarm Thresholds

Context

You can set optical power alarm thresholds using commands. When the transmit or receive power of an optical module exceeds the alarm threshold, an alarm is generated, indicating that the optical module may be faulty.

An optical module has default optical power alarm thresholds, which are fixed and cannot be changed. The configured optical power alarm thresholds must be within the default range. The default optical power alarm thresholds are proper values verified by testing. Therefore, it is not recommended to change the alarm thresholds of optical modules. When an optical power alarm is generated, check the optical module and connected fibers first.

NOTE:
  • The system may fail to obtain information about non-Huawei-certified switch optical modules or obtain incorrect information. You are advised to use Huawei-certified switch optical modules.

  • Only enhanced optical modules support the query of optical power information.

  • The XGE interfaces connected to the ET1D2IPS0S00, ET1D2FW00S00, ET1D2FW00S01, and ET1D2FW00S02 cards do not support the configuration of optical power alarm thresholds.

  • The XGE interface connected to the ACU2 card does not support the configuration of optical power alarm thresholds.

Procedure

  1. (Optional) Run:

    display transceiver [ interface interface-type interface-number | slot slot-id ] [ verbose ]

    Conventional, manufacturing, and alarm information about the optical module on a specified interface is displayed.

  2. Run:

    system-view

    The system view is displayed.

  3. Run:

    interface interface-type interface-number

    The interface view is displayed.

  4. Run:

    set transceiver { transmit-power | receive-power } { upper-threshold | lower-threshold } threshold

    Upper and lower alarm thresholds are set for the transmit and receive power of the optical module on the interface. When the transmit or receive power of an optical module exceeds the upper alarm threshold or falls below the lower alarm threshold, an alarm is generated.

Translation
Download
Updated: 2019-08-21

Document ID: EDOC1000142080

Views: 109682

Downloads: 144