Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Setting Mode of a BITS Clock

Setting Mode of a BITS Clock

Context

The BITS clock refers to the clock signal sent from the BITS interface to a network element. The signal would be clock signal or time signal. The signal that a BITS clock receives depends on the signal that the BITS interface sends and receives.

NOTE:

Interconnected devices must use the same transmission mode of the BITS clock.

Procedure

  1. Run:

    system-view

    The system view is displayed.

  2. Run:

    clock bits-type { bps-2m | hz-2m | bps-1544m } { bits0 | bits1 }

    The clock mode is set for the BITS0 or BITS1 clock.

    Or run:
    clock bits-type { dcls-time | 1pps-tod } { in | out } { bits0 | bits1 }

    The time mode is set for the BITS0 or BITS1 clock.

    By default, the BITS clocks adopt the bps-2m mode.