No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

S12700 V200R010C00 Configuration Guide - Reliability

This document describes the configuration of BFD, DLDP, VRRP, SmartLink, CFM, EFM, Y.1731 and MAC swap loopback to ensure reliability on the device.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuration Task Summary

Configuration Task Summary

After basic CFM functions are configured, CFM can work properly. To deploy special CFM functions such as loopback, linktrace, adjusting CFM parameters, and CFM association, perform the configurations according to the following sections.

Table 9-8 describes the CFM configuration tasks.

Table 9-8  CFM configuration task summary

Scenario

Description

Task

Configure basic CFM functions

CFM detects connectivity faults on an end-to-end link.

Configuring Basic Ethernet CFM Functions

Configure loopback

Similar to IP ping, loopback monitors connectivity of a path between a MEP and an RMEP.

Configuring Loopback

Configure linktrace

Linktrace sends test packets and waits for a response to check whether the destination device is reachable.

Configuring Linktrace

Set CFM parameters

By adjusting Ethernet CFM parameters, you can better implement end-to-end connectivity fault detection on the Ethernet.

Setting CFM Parameters

Configure CFM association

CFM can be associated with interfaces and detection protocols to quickly report link faults, ensuring service reliability.

Configuring CFM Association

Translation
Download
Updated: 2019-04-20

Document ID: EDOC1000142090

Views: 81972

Downloads: 100

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next