Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Detecting Minor Link Events

Detecting Minor Link Events

Context

If an EFM entity receives a link event, it sends an Event Notification OAMPDU to notify the remote EFM entity of the event. The EFM entity also sends a trap to an NMS. After receiving the trap on the NMS, an administrator can determine the network status and take necessary measures.

Select one or more detection methods to monitor links based on your needs.

EFM can be configured on Layer 2 and Layer 3 Ethernet interfaces. By default, an Ethernet interface works in Layer 2 mode. Before configuring EFM on a Layer 3 Ethernet interface, switch the Ethernet interface to Layer 3 mode.

Procedure

  • Detecting errored code events

    1. Run:

      system-view

      The system view is displayed.

    2. Run:

      efm enable

      EFM is enabled globally.

    3. Run:

      interface interface-type interface-number

      The view of the interface at one end of the link is displayed.

    4. (Optional) On an Ethernet interface, run undo portswitch

      The interface is switched to Layer 3 mode.

      By default, an Ethernet interface works in Layer 2 mode.

    5. Run:

      efm error-code period period

      The period for detecting EFM errored codes is set.

      By default, the period for detecting errored codes on an interface is 1 second.

    6. Run:

      efm error-code threshold threshold

      The threshold for detecting EFM errored codes is set.

      By default, the threshold for detecting errored codes on an interface is 1.

    7. Run:

      efm enable

      EFM is enabled on the interface.

    8. Run:

      efm error-code notification enable

      The interface is enabled to detect EFM errored codes.

      By default, an interface is not enabled to detect EFM errored codes.

  • Detecting errored frame events

    1. Run:

      system-view

      The system view is displayed.

    2. Run:

      efm enable

      EFM is enabled globally.

    3. Run:

      interface interface-type interface-number

      The view of the interface at one end of the link is displayed.

    4. (Optional) On an Ethernet interface, run undo portswitch

      The interface is switched to Layer 3 mode.

      By default, an Ethernet interface works in Layer 2 mode.

    5. Run:

      efm error-frame period period

      The period for detecting EFM errored frames is set.

      By default, the period for detecting errored frames on an interface is 1 second.

    6. Run:

      efm error-frame threshold threshold

      The threshold for detecting EFM errored frames is set.

      By default, the threshold for detecting errored frames on an interface is 1.

    7. Run:

      efm enable

      EFM is enabled on the interface.

    8. Run:

      efm error-frame notification enable

      The interface is enabled to detect EFM errored frames.

      By default, an interface is not enabled to detect EFM errored frames.

  • Detecting errored frame seconds

    1. Run:

      system-view

      The system view is displayed.

    2. Run:

      efm enable

      EFM is enabled globally.

    3. Run:

      interface interface-type interface-number

      The view of the interface at one end of the link is displayed.

    4. (Optional) On an Ethernet interface, run undo portswitch

      The interface is switched to Layer 3 mode.

      By default, an Ethernet interface works in Layer 2 mode.

    5. Run:

      efm error-frame-second period period

      The period for detecting EFM errored frame seconds is set.

      By default, the period for detecting errored frame seconds on an interface is 60 seconds.

    6. Run:

      efm error-frame-second threshold threshold

      The threshold for detecting EFM errored frame seconds is set.

      By default, the threshold for detecting errored frame seconds on an interface is 1.

    7. Run:

      efm enable

      EFM is enabled on the interface.

    8. Run:

      efm error-frame-second notification enable

      The interface is enabled to detect errored frame seconds.

      By default, an interface is not enabled to detect errored frame seconds.