S12700 V200R010C00 Configuration Guide - Reliability

This document describes the configuration of BFD, DLDP, VRRP, SmartLink, CFM, EFM, Y.1731 and MAC swap loopback to ensure reliability on the device.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring Association Between CFM and BFD

Configuring Association Between CFM and BFD

Context

For details on the principle and usage scenarios of association between CFM and BFD, see Fault Information Advertisement Between CFM and Other Modules.

Association between CFM and BFD is bidirectional. When CFM detects a link fault, it will notify BFD of the fault. When BFD detects a link fault, it will notify CFM of the fault.

The following types of BFD sessions can be used:
  • Static BFD for LSP (LDP, TE, TE LSP, and static LSP) sessions (a PST is required)

  • BFD for IP sessions (no PST is required)

Perform the following operations on the device of a link configured with CFM at one side and BFD at the other side.

Pre-configuration Tasks

Before configuring association between CFM and BFD, complete the following tasks:

Procedure

  1. Run:

    system-view

    The system view is displayed.

  2. Run:

    oam-mgr

    The OAM management view is displayed.

  3. Run the following commands as required.

    Table 9-16  Association between CFM and BFD
    Scenario Configuration Solution 1 Configuration Solution 2

    Faults need to be transmitted bidirectionally between CFM and BFD.

    Run the oam-bind cfm md md-name ma ma-name bfd-session bfd-session-id command to configure BFD and CFM to report faults to each other.

    NOTE:

    If the oam-bind cfm md md-name ma ma-name bfd-session bfd-session-id command is run, oam-bind ingress bfd-session bfd-session-id egress cfm md md-name ma ma-name and oam-bind ingress cfm md md-name ma ma-name egress bfd-session bfd-session-id will be displayed in the configuration file.

    Use the following commands:
    • Run the oam-bind ingress bfd-session bfd-session-id egress cfm md md-name ma ma-name command to configure BFD to report faults to CFM.

    • Run the oam-bind ingress cfm md md-name ma ma-name egress bfd-session bfd-session-id command to configure CFM to report faults to BFD.

    Faults need to be transmitted unidirectionally between CFM and BFD.

    Choose either of the following commands based on the transmission direction:
    • Run the oam-bind ingress bfd-session bfd-session-id egress cfm md md-name ma ma-name command to configure BFD to report faults to CFM.

    • Run the oam-bind ingress cfm md md-name ma ma-name egress bfd-session bfd-session-id command to configure CFM to report faults to BFD.