Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Modified BFD Parameters Do Not Take Effect

Modified BFD Parameters Do Not Take Effect

Common Causes

After BFD session parameters are modified, the configuration is not committed.

NOTE:

Saving the results of each troubleshooting step is recommended. If your troubleshooting fails to correct the fault, you will have a record of your actions to provide technical support personnel.

Procedure

  1. Run the display current-configuration configuration bfd-session command to check the BFD session configuration and check whether the commit command is used.

    • If the commit command is used, the modified BFD parameters are committed.

    • If the commit command is not used, the modified BFD parameters are not committed. Run the commit command to commit the configuration.