No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

S12700 V200R010C00 Configuration Guide - WLAN-AC

This document describes native AC (hereinafter referred to as WLAN AC) configuration procedures and provides configuration examples.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
(Optional) Configuring CAPWAP Heartbeat Detection

(Optional) Configuring CAPWAP Heartbeat Detection

Context

As defined by CAPWAP, an AP and AC periodically exchange packets to maintain connectivity of the data channel and management channel. If the AP or AC does not receive any response from each other after CAPWAP heartbeat packets are sent for the specified number of times, the AP and AC consider the link between them disconnected.

Perform the following configurations on the active and standby ACs:

Procedure

  1. Run:

    system-view

    The system view is displayed.

  2. Run:

    capwap echo { interval interval-value | times times-value } *

    The CAPWAP heartbeat detection interval and number of heartbeat packet transmissions are configured.

    By default, the CAPWAP heartbeat detection interval is 25s and the number of CAPWAP heartbeat detections is 6.

    By default, If dual-link backup is enabled, the CAPWAP heartbeat detection interval is 25s and the number of CAPWAP heartbeat detections is 3.

    NOTE:

    If you set the CAPWAP heartbeat detection interval and the number of CAPWAP heartbeat detections smaller than the default values, the CAPWAP link reliability is degraded. Exercise caution when you set the values. The default values are recommended.