No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

MIB Reference

S12700 V200R010C00

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ifStackTable

ifStackTable

The table containing information on the relationships between the multiple sub-layers of network interfaces. In particular, it contains information on which sub-layers run 'on top of' which other sub-layers, where each sub-layer corresponds to a conceptual row in the ifTable. For example, when the sub-layer with ifIndex value x runs over the sub-layer with ifIndex value y, then this table contains: ifStackStatus.x.y=active.

The index of this table is ifStackHigherLayer, ifStackLowerLayer.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.2.1.31.1.2.1.1

ifStackHigherLayer

Integer

Not-accessible

The value of ifIndex corresponding to the higher sub-layer of the relationship.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.2.1.31.1.2.1.2

ifStackLowerLayer

Integer

Not-accessible

The status of the relationship between two sub-layers.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.2.1.31.1.2.1.3

ifStackStatus

RowStatus

Read-create

The status of the relationship between two sub-layers. Changing the value of this object from 'active' to 'notInService' or 'destroy' will likely have consequences up and down the interface stack.

Currently, the maximum access is read-only.

Creation Restriction

This table cannot be created.

Modification Restriction

This table cannot be modified.

Deletion Restriction

This table cannot be deleted.

Access Restriction

None.

Translation
Download
Updated: 2019-08-21

Document ID: EDOC1000142096

Views: 161085

Downloads: 77

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next