No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

MIB Reference

S12700 V200R010C00

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwY1731BaseConfigTable

hwY1731BaseConfigTable

This table is used to configure the PW forwarding mode and the threshold for one-way or two-way delay measurement.

The indexes of this table are hwDot1agCfmQueryMdIndex and hwDot1agCfmQueryMaIndex.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.136.1.8.1.1.1.1

hwY1731PwMeasureMode

INTEGER { invalid(1), symmetry(2), asymmetry(3) }

Read-write

PW forwarding mode:
  • invalid

  • Symmetry

  • Asymmetry

When the MA map to a VLAN, the value of this object is invalid.

When the MA map to a VSI or VLL the default value of this object is asymmetry.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.136.1.8.1.1.1.2

hwY1731OneDelayThreshold

Unsigned32

Read-write

This object indicates the threshold for one-way delay measurement.

If hwY1731OneDelayThreshold is set to 0, the default alarm threshold of the one-way frame delay is used. By default, no alarm threshold of the one-way frame delay is set.

Currently, the threshold can be set only when one-way delay measurement is configured in a VLAN.

1.3.6.1.4.1.2011.5.25.136.1.8.1.1.1.3

hwY1731TwoDelayThreshold

Unsigned32

Read-write

This object indicates the threshold for two-way delay measurement.

If hwY1731TwoDelayThreshold is set to 0, the default alarm threshold of the two-way frame delay is used. By default, no alarm threshold of the two-way frame delay is set.

Currently, the threshold can be set only when two-way delay measurement is configured in a VLAN.

Creation Restriction

No entry can be created in this table.

Modification Restriction

None.

Deletion Restriction

None.

Access Restriction

None.

Translation
Download
Updated: 2019-08-21

Document ID: EDOC1000142096

Views: 178071

Downloads: 80

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next