MIB Reference

S12700 V200R010C00

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
nqaAdminParaExtTable

nqaAdminParaExtTable

The indexes of this table are nqaAdminCtrlOwnerIndex and nqaAdminCtrlTestName.

Objects in this table are used in pairs. In each pair, one object is a read-only string and will be filled up after the test instance type is specified. Its value identifies the meanings and value range of the other object. The other object in the pair indicates NQA parameters, whose meanings and value ranges vary with test instances. The type of a test instance is specified by the object in the string form. The first 15 paired objects are numerical parameters and the last 15 paired objects are character string parameters.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.111.2.5.1.1

nqaAdminExtPara1

OctetString

Read-only

This object indicates the description of nqaAdminExtPara2. After the test instance type is specified, the system automatically assigns the object value.

If NQA test type is lspping or lsptrace, then the string is: Specify the destination node id parameter between 0 and 127.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.111.2.5.1.2

nqaAdminExtPara2

Integer32

Read-write

This object indicates NQA parameters that can be configured. After the test instance type is specified, the value and meanings of this object are defined in nqaAdminExtPara1.

The object values have different meanings for different NQA test instance types.

  • For an NQA VPLS PW trace test instance, the object value indicates whether all devices along LSP, including Ps, are displayed.
    • 1: All devices along LSP, including Ps, are displayed.
    • 2: All devices along LSP, except Ps, are displayed.
  • For an NQA PWE3 ping or PWE3 trace test instance, the object value indicates whether the control word function is disabled.
    • 1: The control word function is disabled.
    • 2: The control word function is enabled.
    The default value is 2.
  • For an NQA ICMP test instance, the object value indicates whether the specified request packets are forwarded through an IP network.
    • 0: The specified request packets are not forwarded through an IP network.
    • 1: The specified request packets are forwarded through an IP network.
  • For an NQA jitter or ICMP jitter test instance, the object value indicates whether the packet-rewrite-check function is enabled.
    • 0: The packet-rewrite-check function is enabled.
    • 1: The alternant-binary is specified (bits 0101 and 1010 are alternatively padded into test packets).
    • 2: The same-binary is specified (full 0s and full 1s are alternatively padded into test packets).
  • For an NQA LSP ping or LSP trace test instance, the object value indicates the sink node ID, ranging from 0 to 127.

1.3.6.1.4.1.2011.5.25.111.2.5.1.3

nqaAdminExtPara3

OctetString

Read-only

This object indicates the description of nqaAdminExtPara4. After the test instance type is specified, the system automatically assigns the object value.

If NQA test type is lspping or lsptrace, then the string is: Specify the direction parameter, default is 0, means undo this parameter, 1 means east, 2 means west.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.111.2.5.1.4

nqaAdminExtPara4

Integer32

Read-write

This object indicates NQA parameters that can be configured. After the test instance type is specified, the value and meanings of this object are defined in nqaAdminExtPara3.

The object values have different meanings for different NQA test instance types.

  • For an NQA PWE3 ping or PWE3 trace test instance, the object value indicates the TTL copy mode.
    • 0: The TTL copy mode is unknown.
    • 1: The TTL copy mode is pipe.
    • 2: The TTL copy mode is uniform.
    The default TTL copy mode is unknown, indicating that the system determines the copy mode.
  • For an NQA LSP ping or LSP trace test instance, the object value indicates the test direction.
    • 0: No test direction is set.
    • 1; The test instance is performed in east direction.
    • 2: The test instance is performed in west direction.
    The default value is 0.

1.3.6.1.4.1.2011.5.25.111.2.5.1.5

nqaAdminExtPara5

OctetString

Read-only

This object indicates the description of nqaAdminExtPara6. After the test instance type is specified, the system automatically assigns the object value.

If NQA test type is lspping or lsptrace, then the string is: Specify the ring id parameter between 0 and 65535.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.111.2.5.1.6

nqaAdminExtPara6

Integer32

Read-write

This object indicates NQA parameters that can be configured.

After the test instance type is specified, the value and meanings of this object are defined in nqaAdminExtPara5.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.111.2.5.1.31

nqaAdminExtPara31

OctetString

read-only

This object indicates the description of the nqaAdminExtPara32 object.

The value is automatically assigned by the system after the type of the test case is ascertained.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.111.2.5.1.32

nqaAdminExtPara32

OctetString

read-write

This object is a configurable NQA parameter object.

Its value and meaning are assigned by the nqaAdminExtPara31 object after the test case is ascertained.

The supported NQA test type is pwe3ping.

Creation Restriction

No entry can be created in this table.

Modification Restriction

The entries in this table cannot be modified.

Deletion Restriction

The entries in this table cannot be deleted.

Access Restriction

The entries in this table can be read without restriction.