Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwRrppDomainTable

hwRrppDomainTable

This table describes the information about the attributes of the RRPP domain.

The index of this table is hwRrppDomainID.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.113.2.1.1.1

hwRrppDomainID

INTEGER (1..64)

Not-accessible

The value of this object identifies the domain ID. The ID of the RRPP domain is an integer.

A set of interconnected switch clusters configured with the same domain ID and control VLAN constitute an RRPP domain.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.113.2.1.1.2

hwRrppDomainControlVlanID

Integer (1..4093 | 65535)

Read-create

The value of this object identifies the control VLAN ID. In comparison with the data VLAN, the control VLAN is used to transmit only the RRPP protocol packet in the RRPP domain. Each RRPP domain is configured with two control VLANs, that is, the major control VLAN and sub control VLAN.

During the configuration, specify only the major control VLAN, and the VLAN with the ID as the control VLAN ID plus one becomes the sub control VLAN. The value of the major control VLAN ranges from 1 to 4093 or 65535.

When the control VLAN is not configure, the value of this object is 65535.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.113.2.1.1.3

hwRrppDomainHelloTime

Integer(1..10)

Read-create

The value of this object identifies the timeout period of the Hello timer. The value ranges from 1 to 10, expressed in seconds. The default value of this object is 1 second.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.113.2.1.1.4

hwRrppDomainFailTime

Integer (3..1200)

Read-create

The value of this object identifies the timeout period of the Fail timer. The value ranges from 3 to 1200, expressed in seconds. The default value of this object is 6 seconds. The value of this object cannot be smaller than the value that is three times the value of hwRrppDomainHelloTime.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.113.2.1.1.5

hwRrppDomainRowStatus

RowStatus

Read-create

The object indicates the row status of this table.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.113.2.1.1.6

hwRrppDomainResetStatistics

Integer

Read-create

Clears the statistics of packets received and sent on the current domain.
  • cleared(1)

  • unused(2)

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.113.2.1.1.8

hwRrppDomainProtectedVlan

OctetString min: 0 max: 49

Read-create

Information about the instances bound to the RRPP domain. Both the ID and the number of the instances can be obtained through the object.

NOTE:
The instance ID must be in the range of 0 to 48. This object cannot obtain IDs and number of instances with instance IDs out of this range. A maximum of 49 instances are supported. This object cannot obtain the IDs and number of excess instances.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.113.2.1.1.9

hwRrppDomainDescription

OCTET STRING (SIZE (0..255))

read-create

This object indicates the description of the RRPP domain.

The default value is null.

If the value is empty, the description of the RRPP domain is deleted.

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

The specified control VLAN must be a VLAN that has not been created. The default ID is 65535.

Modification Restriction

The value of hwRrppDomainFailTime must be equal to or greater than three times the value of hwRrppDomainHelloTime.

Deletion Restriction

Before you delete a domain, make sure that no RRPP ring is configured in the domain. Otherwise, the domain cannot be deleted.